In article <348 at spock.UUCP>, blyman at spock.UUCP (Bill Lyman ) writes:
> Okay I give up. I am trying to get a 3b2310 to call a machine between
> 1:00 am and 2:00 am in the morning. My System entry is as such.
> Machine_name 0100-0200 ACU 1200 phone_no _________ etc
> My poll statment is as follows
> Machine_name 1
>
> It is giving me messages that it is the wrong time to call. I have tried
> 2200-0300 and it stills say wrong time to call.
This common problem is cause by cron not knowing how to export the
proper TZ (timezone) environment variable; the default EST5EDT gets
used. This can be fixed three ways:
(1) move to New Jersey
(2) get SVR3 -- it handles TZ correctly
(3) put ". /etc/TIMEZONE" everywhere.
Option (3) means you need to add the above line to the beginning
of /usr/lib/uucp/uudemon.poll and /usr/lib/uudemon.hour if you are
using the standard Poll scheme, or at the top of your shell scripts.
There are other solutions to the incoming-mail-has-the-wrong-time
problem, but that is for another day.
MORAL: Always include ". /etc/TIMEZONE" at the start of scripts
run from cron.
--