UNIXPC Power Supply Specifications
C M Votava
cmv at ihlpm.ATT.COM
Sat Feb 6 02:29:59 AEST 1988
I've seen a bunch of questions about the technical specifications for the
unix-pc power supply, and thought I could offer some help. Below is some
preliminary specifications on the power supply that I've come across. I
can't tell if these actually became part of the end product or not, so take
them with that in mind.
PRIMARY MODULATION:
The power supply is a switching regulator supply that uses primary
pulse width modulation to control the output voltages, independent of
line voltage and DC load variation. The modulating frequency is 20KHz
or higher.
PRIMARY PROTECTION:
To protect the primary section of the supply against abnormal overloads
from any of the DC outputs, the supply should have a constant current
or current recycling circuit to allow for the safe power up of large
capacitive loads. The primary in rush current during power up (from
cold start) should be limited to 34 AMPS peak (for 110V).
OPERATING ENVIRONMENT:
operating temperature range: 10C to 60C
non-operating temperature range: below 40C and above 75C
humidity 5-95%
operating altitude: 15,000 Ft. ASI
non-operating altitude: 25,000 Ft. ASI
POWER TO FANS:
There shall be a +12v supply to two 3" fans, with a temperature switch
which allows full voltage to the fans at 45C.
PARAMETER CONDITIONS MIN TYP MAX
========================================================================
V1 Output Voltage Min.<=I1<=Max. 4.95V 5.00V 5.05V
0<=I2, I3<=Max.
V2 Output Voltage Min.<=I1, I2, I3<=MAX. 11.76V 12.00V 12.24V
V3 Output Voltage Min.<=I1, I2, I3<=Max. -11.40V -12.00V -12.60V
I1 Output Current(V1) V1=5.00V 5A 20A
I2 Output Current(V2) V2=12.00V .75A 3.0A
I3 Output Current(V3) V3=-12.00V .05A .3A
Output Power V1, V2, V3=Max 163W for 10sec
from power
on
139.6W
Hope this helps...
More information about the Comp.sys.att
mailing list