Info-3b2 Digest, Number 49
Info-3b2 Mailer
info-3b2 at lamc.UUCP
Sat Jan 7 08:33:23 AEST 1989
Info-3b2 Digest, Number 49
Friday, January 6th 1989
Today's Topics:
Re: Info-3b2 Digest, Volume 47
Ports giving trouble
----------------------------------------------------------------------
Subject: Re: Info-3b2 Digest, Volume 47
Date: 5 Jan 89 10:54:14 EST (Thu)
From: cogsci!ucbvax.Berkeley.EDU!ames!mailrus!umix!cfctech!alexb (Alex Beylin)
In article <1652 at lamc.UUCP> you write:
>
>
> Info-3b2 Digest, Number 47
>
> Wednesday, January 4th 1989
>
>Today's Topics:
>
> Re: Intermittent Ports Hanging
>----------------------------------------------------------------------
>
>From: cogsci!cs.buffalo.edu!sigmast!dgy
>Subject: Re: Intermittent Ports Hanging
>Date: Tue, 3 Jan 89 8:29:34 EST
>
>> Has anyone experienced ports problems,primarily with cu while
>> using either the eports or standard ports hardware? It seems that
>> .............
>I'm glad someone else is having this problem! We are also running 3.1.1
>with eports 1.2, and have the same problem. In our case, it usually
>happens when someone is dialed out to a VAX with VMS, at 1200 or 2400,
>and it doesn't matter if the modem itself is on the eports board, just
>the terminal being used. The entire board locks and we have to reboot.
^^^^^^
A better, though more involved soultion to a locked-up eport card is
as following:
Assume eport board #60 is locked-up.
1. /etc/pump /dev/tty61 /lib/pump/eports
^^^^^^^^^^
(first port)
2. ps -ef | grep tty6?
3. Go through the list of left-over processes generated
with "ps" above and "kill -9 " them all.
4. init q; init q
This will still blow-off all the users on the board, but will
not disrupt users on other eport cards.
=================================================================
Alex Beylin | +1 313 244 3386
alexb at cfctech.UUCP | Chrysler Financial Corp.
alexb%cfctech.uucp at umix.cc.umich.edu | MIS, Technical Services
{sharkey,umix,mailrus}!cfctech!alexb | 901 Wilshire, Troy, MI
-----------------------------------------------------------------
DISCLAMER: Any opinions expressed here are are my own and
may be contrary to polices or procedures of my employer.
=================================================================
------------------------------
Subject: Ports giving trouble
Date: Fri, 6 Jan 89 20:09:32 GMT
From: Graham Glen (Technical Manager) <hoptoad!graham%quaduk>
We used to have all sorts of problems with the ports on our 3B2, loosing
every other character in each direction. This seemed to be exacerbated by
using cu frequently.
One thing that you might wish to try (If you haven't already done so) which
cured the problem for us is increasing NCLIST, I currently have ours
set to 256 (which is probably extreme overkill...), and now the only
problems we have are the occasional flow control problems on 9600 baud
modems. On an XPIO card we normally run either 4 terminals at 9600 or 2 at
19200, and apart from the original problem have never had a ports board
hang.
I hope that might be of some interest/help to someone.
Graham
--
Graham Glen
Quadratron Systems (UK) Ltd.
Voice: +44 1 371 5755 Fax: +44 1 736 1071 Telex: 267500 LIBORG G
+44 836 380006 (mobile)
{quad1,qnorth,qswiss,ukc,attunix!uel}!quaduk!graham
-------------------------------------
To join this group or have your thoughts in the next issue, please
send electronic mail to Ken Davis at the following address;
{pacbell,netsys,hoptoad,well}!lamc!info-3b2-request
The views expressed in Info-3b2 Digest are those of the
individual authors only.
*********************
End of Info-3b2 Digest
*********************