TB+ on a 3B2/300???
Cerafin E Castillo
cec at cup.portal.com
Wed Nov 7 07:18:24 AEST 1990
Sounds like there's a getty battle going on at one of the two
modems. Make sure that they're set-up right for a getty. A
hang-up usually indicates that E1 and Q0 should be set to E0
and Q6, possibly.
Anyways, call TELEBIT at 1-800-TELEBIT and have them e-mail you
the UNIX.setup and UNIXPC.setup guides. You can down load these
(UUCP) from UUNET [~ftp/telebit-info/UNIX.setup.Z] via their
1-900-GOT-SRCS number and an nuucp/uucp (?) login or direct, if
you have a uunet uucp account. Let me know if you have any
problems. Good Luck!
===============================================================================
Cerafin E. Castillo || //\\ ||\\ ||
Network Consultant || //__\\ || \\ || Los Altos
Los Altos Networks || // ---\\|| \\|| Networks
340 Second St. #6 ||___// \|| \\|
Los Altos, CA 94022
(415) 941-8031 UUCP: {apple,sun,uunet}!portal!cup.portal.com!cec
NTERNET: cec at cup.portal.com
"...No hay mal que por bien no venga..."
===============================================================================