4D35 Disks (I'm being bit) with Details!
Dave Olson
olson at anchor.esd.sgi.com
Mon Jun 10 06:12:38 AEST 1991
In <1991Jun8.054208.18831 at nntp-server.caltech.edu> woolstar at nntp-server.caltech.edu (John D. Woolverton) writes:
| I had a nice, quiet, third party hitachi 3 1/2 drive in
| my temporary 4d25, and when they upgraded to the 4d35, it
| stopped working.
| Someone mentioned that the SCSI controllers changed from
| SCSI1 to SCSI2.
...
| The dirty details of my trials,
| Upon BOOT UP:
| SCSI device/cable diagnostic *FAILED*
| Diagnostic failed
|
| This unit is in the periferal(sp?) bay with the tape drive.
| Suspecting the mounting bracket, I switch the two, but had the
| same failure with the disk drive again.
| Telling the machine to boot anyways...
This is probably the senddiag or startunit command failing; if
you boot ide, interrupt it, do 'set report 4', then run 'scsi',
you should be able to tell for sure.
| Jun 7 22:14:34 sgi grcond[190]: In limbo
| Alive
| driver error 1
| dks0d1s0: invalid sense data, can't determine cause of error
| dks0d1s0: retrying request
| sc0,2,0: Unexpected info phase 46, state 49. Resetting SCSI bus
| At this point, I'm wondering if this mess is properly terminated.
| I'll probably go over it with a fine tooth comb again this weekend,
| and maybe I'll be up and working. It's a problem.
My best guess is indeed that you have termination or cabling
problems. phase 46 state 49 means that the scsi chip expected
a status phase because the byte count had dropped to 0, but the
device was sending more data instead. This is almost always caused
by cabling / termination, although in rare cases it can be drive firmware
or driver bugs; for disk drives it is almost alway cabling/termination.
--
Dave Olson
Life would be so much easier if we could just look at the source code.
More information about the Comp.sys.sgi