/etc/inetd is sensitive to ordering of lines in /etc/inetd.conf
Tim Roper
munnari!labtam.oz.au!timr at uunet.uu.net
Wed Apr 26 11:58:46 AEST 1989
I think the attached diff of the 4.3bsd and 4.3bsd-tahoe inetd.c may be of
interest. The se_bi flag in the data structure that holds /etc/inetd.conf
was not being reset when a non-internal entry was encountered after an
internal entry. Hence the problem described in
<8903061946.AA20555 at emoryu1.cc.emory.edu>
I have no idea how SunOS versions relates to these. We encountered the
problem with a System V implementation derived from bsd (for which a fix
was issued by the TCP supplier well before tahoe was announced).
-Tim.
***************
*** 593,622 ****
if (strcmp(sep->se_server, "internal") == 0) {
register struct biltin *bi;
for (bi = biltins; bi->bi_service; bi++)
if (bi->bi_socktype == sep->se_socktype &&
strcmp(bi->bi_service, sep->se_service) == 0)
break;
if (bi->bi_service == 0) {
syslog(LOG_ERR, "internal service %s unknown\n",
sep->se_service);
goto more;
}
sep->se_bi = bi;
sep->se_wait = bi->bi_wait;
! } else
! sep->se_bi = NULL;
argc = 0;
for (arg = skip(&cp); cp; arg = skip(&cp))
if (argc < MAXARGV)
sep->se_argv[argc++] = strdup(arg);
while (argc <= MAXARGV)
sep->se_argv[argc++] = NULL;
return (sep);
}
freeconfig(cp)
register struct servtab *cp;
{
int i;
More information about the Comp.sys.sun