SCSI kernel config info needed for 4/260
Steve Maraglia
srm at unify.com
Sat Jan 12 09:52:11 AEST 1991
Configuration:
o 4/260 running 4.1, 1 Xylogic controller and 1 SCSI-3 host adapter
o 1 SMD disk
o 4 SCSI disks & 1 1/4" tape drive
Question:
o I want to add a 5th scsi disk and I'm not sure how to address it. I'm
currently using sd0 (Physical dr#0), sd2 (dr#1), sd4 (dr#2) & sd6 (dr#3).
What physical address correlates to sd1 & sd3 ??
"sd3 at si0 drive 9 flags 0"
^^^^^^^
o How does drive # above correlate to the drives physical address?
Kernel:
o SCSI-3 entry in my kernel configuration file.
#
controller si0 at vme24d16 ? csr 0x200000 priority 2 vector siintr 0x40
disk sd0 at si0 drive 0 flags 0 # Physical address 0
disk sd1 at si0 drive 1 flags 0 # Physical address ???
disk sd2 at si0 drive 8 flags 0 # Physical address 1
disk sd3 at si0 drive 9 flags 0 # Physical address ???
disk sd4 at si0 drive 16 flags 0 # Physical address 2
disk sd6 at si0 drive 24 flags 0 # Physical address 3
tape st0 at si0 drive 32 flags 1 # Physical address 4
tape st1 at si0 drive 40 flags 1 # Physical address 5 ??
Steve Maraglia internet: srm at unify.com
Unify Corporation ..!{uunet,csusac,pyramid}!unify!srm
3870 Rosin Court Sacramento, CA 95834 (916) 920-9092