In article <1990Nov29.181905.26620 at hawkmoon.MN.ORG> det at hawkmoon.MN.ORG (Derek E. Terveer) writes:
|kdq at demott.COM (Kevin D. Quitt) writes:
|
|> If you've a Telebit modem, register S41 can be set in tenths of
|>hours, from 0 (disabled) to 255. When the timer expires, the modem
|>hangs up the line.
|
|(I presume you are talking about the trailblazer series of modems)
|Unfortunately, not all of the Telebit modems support this feature. I have a
|Trailblazer Plus and it does not have register 41.
Trailblazer+'s, if upgraded to ROM revision BC5.10A (probably any 5.x
variety) will have the register available...