Problem with modem on S2 serial port
    Mike Stefanik/78125 
    mike at bria.AIX
       
    Fri Dec 28 23:49:09 AEST 1990
    
    
  
I having a bit of a problem with an RS/6000 and a modem on the 
S2 serial port.  I'm running 3.1 (3002 updates), and have a 
Multitech 224E sitting on the S2 port (and, of course, using a 
standard IBM modem cable for said port).  The port is the standard
2400 bps, 81N, and *enabled* for login (not shared; that doesn't seem
to work *at all*, even with 3002 applied).
The problem is that when I try to dial up the system, I get a
connect, but no login.  Now, what is interesting is that *infrequently*
when two "pdisable" and two "penable" commands are issued, such as:
     # pdisable tty1; pdisable tty1; penable tty1; penable tty1
I have gotten a login, and from that point on was able to login 
consistently.  However, once the machine is rebooted, it goes on the
fritz again.
BTW: There is a getty on the port at the time ...
Anyone out there have any ideas?
-----------------------------------------------------------------------------
Michael Stefanik, Systems Engineer (JOAT), Briareus Corporation
UUCP: ...!uunet!bria!mike
"If it was hard to code, it should be harder to use!"
    
    