In article <288 at mtxinu.UUCP> kridle at mtxinu.UUCP (Bob kridle) writes:
>In article <2771 at ihlpa.UUCP> ppk at ihlpa.UUCP (Kells) writes:
>>
>>	I am looking for a good method to test DMC/DMR11
>>synchronous controllers on a DEC VAX 11/780-5. The diagnostics
>>supplied by DEC seldom indicate impaired performance unless
>>a board is in major trouble. This can be very frustrating!!
>>The VAX is running UNIX system V.2. ANY information --
>>sincerely appreciated.
>>	
> Several years ago, I installed
>a DEC DMC11 and discovered it would pass the external loopback test
>without having the loopback installed!
>

We have a VAX-11/750 and suffer from the same
problems! The DEC diagnostics for DEUNA showed it had passed
all it tests even though we did NOT have the loopback installed!
			sharan kalwani
			...!ihnp4!mb2c!mcf!shan
-- 
				
		       fff	Sharan Kalwani
		      ff ff	Dept. of Physiology & Biophysics
		      ff	Michigan Cancer Foundation
m mmm mmm    ccccc  fffffff	110 East Warren Avenue		
 m   m   m  c     c   ff	Detroit, Michigan 48201
 m   m   m  c         ff	UUCP:  	 	!ihnp4!mb2c!mcf!shan
 m   m   m  c     c   ff	alternate:	(313) 833-0710 x411
mmm     mmm  ccccc    ff				       x262
--