Help with uda errors
Chris Torek
chris at mimsy.UUCP
Wed Dec 21 13:23:45 AEST 1988
In article <17846 at adm.BRL.MIL> Hampton at dockmaster.arpa (David R. Hampton)
writes:
>I am running BSD 4.2 on a VAX 11/785, using the University of Maryland
>uda driver. The modification time on my driver is 19 December 1985.
You have an ancient edition (but then, you have 4.2BSD...). It probably
mostly works. I have nothing decent for 4.2BSD though.
>uda0: soft error, disk transfer error, unit 1, grp 0x0, hdr 0x3f038,
> event 0313
The important number is the `event'. 0313 translates to `lost receiver
ready drive error'. `hdr 0x3f038' here says that the drive was working
on block 258104---probably irrelevant in this case. The receiver probably
refers to the UART receiver for the serial cable between the controller
and the drive. (This is a WAG.)
>uda0: soft error, SDI error, unit 1, event 0353, hdr 0x0
>uda0: hard error, disk transfer error, unit 1, grp 0x0, hdr 0x4cce8,
> event 0313
I have never figured out what makes an error an `SDI error', but 0353
is `drive detected error drive error'---not very informative, other than
that the drive's error checking code thinks something is wrong. Here
you got one lost-receiver-ready, so it retried and got a drive-detected-
error, and gave up.
>P.S. DEC was just here yesterday for our monthly maintenance visit. I
>had not seen any errors before then. Could they have changed something
>that would cause this?
Check the cables. One is probably loose, or bent.
--
In-Real-Life: Chris Torek, Univ of MD Comp Sci Dept (+1 301 454 7163)
Domain: chris at mimsy.umd.edu Path: uunet!mimsy!chris
More information about the Comp.unix.wizards
mailing list