UDA50 on VAX 11/730
Michael Enkelis
michaele at vice.ICO.TEK.COM
Wed Feb 28 04:31:36 AEST 1990
I am trying to configure a UDA-50 + RA80 disk drive into my
VAX 11/730 system. Everything seems ok on boot up,
but within 24 hours i get the following messages and the system is hung.
Feb 23 10:18
uda0: soft error, SDI error, unit 0, event 053, hdr 0x0
0x13 0x4 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0
uda0: soft error, SDI error, unit 0, event 0113, hdr 0x0
0x13 0x4 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0
uda0: soft error, SDI error, unit 0, event 0113, hdr 0x0
0x13 0x4 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0
uda0: hard error
uda0: hard error, SDI error, unit 0, event 0113, hdr 0x0
0x13 0x4 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0
uda0: soft error, SDI error, unit 0, event 0113, hdr 0x0
0x13 0x4 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0
uda0: soft error, SDI error, unit 0, event 0113, hdr 0x0
0x13 0x4 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0
uda0: hard error
uda0: hard error, SDI error, unit 0, event 0113, hdr 0x0
0x13 0x4 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0
ra0c: hard error sn64 OFFLINE
My system consistes of:
4.3 BSD UNIX #5: Fri Feb 16 23:27:28 PST 1990
root at enky:/sys/VAX730
real mem = 4194304
avail mem = 3389440
using 153 buffers containing 314368 bytes of memory
mcr0 at tr0
uba0 at tr3
idc0 at uba0 csr 175606 vec 250, ipl 15
rb0 at idc0 slave 0
rb1 at idc0 slave 1
uda0 at uba0 csr 172150 vec 774, ipl 15 <<-- in exp box.
ra0 at uda0 slave 0
zs0 at uba0 csr 17250 vec 224, ipl 15 <<-- in exp box.
ts0 at zs0 slave 0
dmf0: printer synch asynch.
dmf0 at uba0 csr 160340 vec 734, ipl 15
vp reset vec from 200 to 174 <<-- in exp box.
vp0 at uba0 csr 177510 vec 174, ipl 14
Any ideas on jumper setting on UDA? or card placement in exp box.
--
_ _ _ __
' ) ) ) / /) / ` / /) Michael Enkelis
/ / / o _. /_ __. _ // /-- __ /_ _ // o _ tektronix!vice!michaele
/ ' (_(_(__/ /_(_(_(<_(/_ (___, /) )_/ <_(<_(/_(_/_)_ (503) 627-4099
More information about the Comp.unix.wizards