Need help in setting terminal attributes during outgoing "cu"
mike.stefanik
mike at bria.UUCP
Fri Jun 7 09:27:51 AEST 1991
In an article, michael at yonder.UUCP (Michael E. Haws) writes:
>I have an SCO xenix 2.3.2 machine and have the need to adjust the
>port characteristics on an outgoing "cu" connection for this one
>_particular_ machine I need access to. I need to set "ISTRIP" in particular.
A quote from the Holy Tome:
In addition, cu uses the following options to determine communications
settings:
-o If the remote system expects or sends 7-bit with odd parity
-e If the remote system expects or sends 7-bit with even parity
-oe If the remote system expects or sends 7-bit, ignoring parity
and sends 7-bit with either parity
By default, cu expects and sends 8-bit characters without parity.
If the login prompt received appears to contain incorrect 8-bit
characters, or a correct login is rejected, use the 7-bit options
described above.
So, in this case, use -oe. Works fine, lasts a long time.
--
Michael Stefanik, MGI Inc, Los Angeles | Opinions stated are never realistic
Title of the week: Systems Engineer | UUCP: ...!uunet!bria!mike
-------------------------------------------------------------------------------
If MS-DOS didn't exist, who would UNIX programmers have to make fun of?