uucp via tcp/ip
Chip Rosenthal
chip at chinacat.unicom.com
Fri May 24 14:31:17 AEST 1991
In article <21680 at brahms.udel.edu> sabi at brahms.udel.edu
(Sabita Nagarajan) writes:
>SCO xenix 2.3.2 running on my_machine and their_machine
OK...I'll play clairvoyant if you'd like.
Lemme see...hmmmm...hard to say, but I'll guess you are using the
Excelan LAN WorkPlace for XENIX.
>Their_machine Any TCPIP 9600 - "" \r ogin: uucp
The first thing you need to do in the chat script is tell ttyT32 where
to connect. You aren't. Try this:
Their_machine Any TCPIP 9600 - "" Their_machine "" \r ogin: uucp
I'd also expect that \r is unecessary.
--
Chip Rosenthal <chip at chinacat.Unicom.COM> | Don't play so
Unicom Systems Development 512-482-8260 | loud, Mr. Collins.
More information about the Comp.unix.xenix.sco