Request for help in adding terminals to XENIX
grr at cbmvax.UUCP
grr at cbmvax.UUCP
Sun Feb 1 04:44:18 AEST 1987
In article <459 at catnip.UUCP> ben at catnip.UUCP (Bennett Broder) writes:
>In article <1157 at steinmetz.steinmetz.UUCP> davidsen at kbsvax.UUCP (william E Davidsen) writes:
>>I just wish wish Xenix supported 19.2kb...
>
>I notice that you can specify a baud rate of EXTA or EXTB to either stty
>or getty. These are not well documented in the manuals. I have tried
>sttying to them, but they don't currently represent any baud rate supported
>by my terminal. Anybody know what these are for? Maybe it is possible to
>define one of these to be 19200?
>Ben Broder {ihnp4,decvax} !hjuxa!catnip!ben
In the 'real world' if you have 19,200 BPS, it takes the place of, or is
equivalent to EXTA. On the old PDP-11 interfaces just had a '1 of n'
selection where EXTA and EXTB didn't have assigned speeds, but could be
jumpered to random bit-rates. On the PC, the rates are established by
loading a divisor into the INS8250 chip. If EXTA doesn't give you 19200,
then you should be able to patch the divisor table to suit...
--
George Robbins - now working for, uucp: {ihnp4|seismo|rutgers}!cbmvax!grr
but no way officially representing arpa: cbmvax!grr at seismo.css.GOV
Commodore, Engineering Department fone: 215-431-9255 (only by moonlite)