Serial Driver Configuration
Steve Souza @telesoft
souza at telesoft.UUCP
Wed Apr 19 03:34:12 AEST 1989
Hi Folks,
We've recently developed a serial mouse driver for a Unisys PC
running SCO Xenix. Since moving the driver from OS version 2.2(.3?)
to 2.3, the message:
serial: WARNING: interrupt vector collision
has begun to appear. The mouse plugs into either COM1 or COM2,
interrupting on vector levels 4 and 3, respectively. We remove the
vector level associated with the mouse from the standard serial driver
(sio), so the resulting configuration lines look as follows:
sio 3 0577 104 sio 0 0 5 1 7 4 33 34 0
mse 1 0537 104 mse 0 0 27 1 5 3 0 0 0
I don't see a collision here. Is this OS confusion, or are we doing
something weird? Both the mouse and the other serial port (connected to
a terminal) work fine.
Appreciate any suggestions!
Steve Souza ucsd!scubed!opti!souza (619)292-6060
More information about the Comp.unix.xenix
mailing list