SCO UNIX 3.2 difficulty

Brad Templeton brad at looking.on.ca
Fri Oct 6 07:34:41 AEST 1989


Well, I don't have rtsflow or ctsflow set in the gettydefs line.
(I do have a problem with getty where it insists that dialing in logins
come in with 0 parity, which is a pain -- the istrip isn't working)

Here's the gettydefs line

p # EXTA HUPCL ISTRIP #
	EXTA CS8 SANE HUPCL TAB3 ECHOE IXANY #(Telebit 19200) login: # 3

The trick might be in my telebit registers, which are a bit different from
SCO's setup.  But they work with dialTBIT and uugetty.


E0 F1 M1 Q0 T V1 X3     Version BA4.00
S00=001 S01=000 S02=043 S03=013 S04=010 S05=008 S06=004 S07=040 S08=002 S09=006
S10=007 S11=070 S12=050 
S45=000 S47=004 S48=000 S49=000
S50=000 S51=005 S52=002 S53=001 S54=001 S55=003 S56=017 S57=019 S58=002 S59=000
S60=000 S61=045 S62=003 S63=001 S64=000 S65=000 S66=000 S67=000 S68=255 
S90=000 S91=000 S92=000 S95=000 
S100=000 S101=000 S102=000 S104=000 
S110=255 S111=255 S112=001 
S121=000 
N0:
N1:7414080\DATAPAC
N2:(censored)
N3:(censored)
N4:5793225\TYMNET
N5:14162658035\CIS

Every once in a while I will get strange behaviour on dial-OUT when
the relay will click on and off quickly 4 times in a row, but that's rare
and everything seems to be working otherwise.  Just fine at 19.2k

Right now I have the modem connected to a standard COM1.

But it also worked connected to my smart card Intellicon port, which I plan
to switch it over to shortly.
-- 
Brad Templeton, ClariNet Communications Corp. -- Waterloo, Ontario 519/884-7473



More information about the Comp.unix.xenix mailing list